Marine
Rail Vehicles
Cable Assemblies
Romote Vehichles
Home >> News >> News Detail
ARCOLECTRIC Maintenance indicator

                                   Monitors appliance usage
                                   Preventative maintenance reminder
                                   Direct replacement for Neon indicator
                                   Counts time that mains power is applied
                                   Remembers accumulated time even if power is switched off
                                   Connecting &reset* terminal to Neutral resets timer to zero
                                   Blue LED indicates normal operation
                                   Flashing Red LED indicates service action is required
                                   Convenient snap-in design
                                   Fast-on terminals
                                   Bezel size 32 x 14mm

1432AL

Specify Terminal Type: C, H, T, X
Specify Model Code: 1432AL
Specify Supply Voltage: 115Vac, 230Vac, 24Vdc, 12Vdc
Specify LED Colour: Red/Green, Red/Blue
Specify Time Setting: Time interval between 1 minute and 10 years.
Specify the required time in minutes, hours, days,
weeks or months.
Revision 5

230V ㊣20% 50Hz. 115Vac, 24Vdc & 12Vdc available.
Less than 1 watt (power consumption)
UL Pending
CE Mark
RoHS compliant    

APPLICATIONS

 Coffee machines 每 decalcification
 Deep fat fryer 每 oil change
 Air conditioning 每 filter change, bleaching                   
 Vacuum cleaner 每 filter cleaning
 Motorised equipment 每 preventative maintenance, lubrication, belt change
 Petrol/Diesel engine generator 每 engine service
 Central heating 每 gas appliance inspection
 Inspection/cleaning interval reminder 每 washrooms, kitchens
 Equipment calibration interval reminder
 Electrical safety check interval reminder    

 OPERATION

The smart indicator operates like a standard neon indicator, giving visible
status indication for the appliance or application. Normal operation will
show continuous Blue LED illumination (contact factory for other colours).
When the accrued usage time exceeds the factory-set time limit, the LED
illumination changes colour to Red (contact factory for other colours) and
starts to flash on/off to attract user attention. The indicator will continue to
flash on subsequent appliance use, until the maintenance operation is
carried out and the reset procedure followed.
To reset the indicator after maintenance operations are completed, simply
link terminal 2 to terminal 3 while the indicator is powered. This could be a
key-operated switch or a service button within the appliance.
The service interval time is factory programmed, and can be any time
period from as little as one minute, up to tens of years.
4
                                                   

Date:2007/8/29  [ Back ]
2007© Copyright by D&Y Technology Co.,Ltd. Support:innoNT
Tel:+86-755-26067336 86036415 Fax:+86-755-86036416 E-mail:info@dytechnology.net
Add:Floor 8,Jinhui Bldg,Nanhai Blvd,Nanshan Shenzhen,518054,P.R.CHINA,518054,P.R.CHINA