Marine
Rail Vehicles
Cable Assemblies
Romote Vehichles
Home >> News >> News Detail
ARCOLECTRIC Single phase mains supply checker

                                     Monitors appliance and mains supply
                                     Direct replacement for Neon indicator
                                     Equipment safety indication
                                     Checks for swapped connections
                                     Checks for missing connections
                                     Green LED indicates normal operation
                                     Steady Red LED indicates connection fault
                                     Flashing Red LED indicates missing connection
                                     Live, Neutral and Earth connections
                                     Convenient snap-in design
                                     Fast-on terminals
                                    Bezel size 32mm x 14mm

1431AL

Specify Terminal Type: C, H, T, X
Specify Model Code: 1431AL
Specify Supply Voltage: 115Vac, 230Vac
Specify LED Colour: Red/Green, Red/Blue

230V ¡À20% 50Hz. 115Vac 60Hz available.                    
Less than 1 watt (power consumption)
UL Pending
CE Mark
RoHS compliant
TERMINAL FUNCTION     

APPLICATIONS

 Portable appliances
 Site equipment
 Power tools
 Commercial kitchens
 Stainless steel appliances
 Audio equipment
 Consumer units
 Extension cables/reels
 Garden equipment

INDICATIONS

The smart indicator can detect and display the following fault conditions:
Terminal 1   Terminal 2   Terminal 3        Fault                          LED Indication
       L                 N                 E                Normal                               Green
       N                 L                 E            L/N Swapped                           Red
       E                 N                 L            L/E Swapped                           Red
       E                 L                 N            Wrong sequence                     Red
       N                 E                 L           Wrong sequence                      Red
       L                  -                 E           Neutral missing Flashing          Red
       L                 N                  -           Earth missing Flashing             Red

 

 

 

 

 

                                                                                       

 

 

 

 

 

 

 

Date:2007/8/29  [ Back ]
2007© Copyright by D&Y Technology Co.,Ltd. Support:innoNT
Tel:+86-755-26067336 86036415 Fax:+86-755-86036416 E-mail:info@dytechnology.net
Add:Floor 8,Jinhui Bldg,Nanhai Blvd,Nanshan Shenzhen,518054,P.R.CHINA,518054,P.R.CHINA