T type • The T motor protector is designed to protect single phase induction motors against overload and locked rotor conditions up to 65A.
• AUTOMATIC RESET: Main application is protection of hermetic compressor for refrigeration. Models with cover are approved for use with flammable refrigerant gases. • MANUAL RESET: Main application is protection of electric motor where automatic reset would be dangerous or otherwise undesirable (Food Mixers, Chain saws, etc.). Tripfree to assure contact break independent of manual action. GENERAL CHARACTERISTICS
• CONTACT CONFIGURATION: Single pole - Double break - Single throw - N.C. • CONTACT RATING: Low capacity 40A 125Vac, 30A 250Vac; High capacity 65A 125Vac, 50A 250Vac. Above ratings are locked-rotor inductive currents (LRA) • MAXIMUM OPERATING TEMPERATURE: 150¡ãC • OPENING TEMPERATURE: 65¡ãC up to 150¡ãC ( ¡À5¡ãC ) -------------------------------Minimum differential 25¡ãC nominal (or manual) • RESET TEMPERATURE 41¡ãC up to 102¡ãC ( ¡À9¡ãC ) • FIRST CYCLE TRIP CURRENT from 3 to 50A (at 25¡ãC for opening in10 seconds average) • ULTIMATE TRIP CURRENT from 0.6 to 25A • AUXILIARY HEATERS selection of flat or coiled heaters • DISC Different physical sizes, broad range of material resistivity • TERMINAL CONFIGURATION: Quick-Connect tab M3.5 screws Solder terminal Cable leads (AWG 14 or AWG 16)