RVA MOTOR START POTENTIAL RELAY PATENT PENDING RVA potential relay is designed to start single-phase motors which employ both start and run capacitor (CSR and CSIR configurations) for high starting torque. The most frequent applications include air conditioning, commercial refrigeration, heat pump, etc. The coil is energised by the potential of the start winding. When such voltage is raised up to the pickup value, the contact will open and disconnect the start capacitor. The relay will remain energised until the start winding voltage is removed or decreases to less than the drop-out value.
DESIGN DATA Coils: Class ¡°B¡± (130¡ãC) insulation. See table for characteristics. Contact rating: One Normally Close contact RVA standard contact rating: 16A (make and break), 400V, cosj 0.85, 500,000 operations 35A (break only), 400V, cosj 0.85, 200,000 operations RVAH high capacity contact rating: 50A (break only), 400V, cosj 0.85, 100,000 operations Operation: See table for operating characteristics (dependent to mounting position) Specify operating position For Normal pollution conditions (according to EN60730) Approved for use with flammable gas, according to IEC 79-15 Terminals: Quick-Connect or screw M3.5 (see table)
Approvals: VDE 40002454 UL E51436 CSA LR55278-3
electrica_rva.pdf
|