Home >> Product >> Product Detail
product photo

Product Type
Standard DC Power Distribution Center

Product Series
LDM1-Series

Description
LDM1-Series PDF eLibrary

• Hot "swappable" circuit breakers that can be installed, changed, or replaced in the field or factory • Circuit breakers are front panel accessible • Incorporates Carling M-Series hy-mag breakers, the smallest UL489A listed hydraulic-magnetic circuit breaker on the market • Maximum of nine circuit breakers per feed, 18 per panel • Keyed terminal to prevent breaker from being mounted incorrectly • One Rack Unit (1RU) size • Panel plugs provided for non-populated circuit breaker slots Rockerguard circuit breakers to prevent accidental operation • Front accessible removable alarm card • Panel easily configurable and upgradeable in the field, providing flexibility when designing added features or options • Conserves valuable cabinet space • Optional rack extenders to expand panel mounting from a 19" rack to a 23" rack

Series PDF eLibrary

LDM1new.pdf

PDC_7_2003Web.pdf

Standards UL1801, CUL Approved (pending)
Dimension Rack mounts to EIA standard EIA-310-D 19" rack
for a 1RU panel, 1.75" H
Enclosure 16 gauge yellow zinc chromate cold rolled steel
Feeds Dual feeds, rated up to 150 amps per feed
Maximum circuit breakers per feed: 9
Maximum breaker rating: 25 amps
Connections: two hole compression lugs for 1/4 - 20 stud terminals x 5/8 centers
Load Connections Requires 10 awg wire/ring or fork terminal for 25A/75 degrees C Rating, top or bottom wire entry
Operating Voltage -36V to -60V DC (-48VDC nominal)
Alarm Feature Power alarm: If either A or B Feed fail or both fail
Breaker Alarm: If any populated breaker is OFF or "tripped".
Alarm is not affected by unused breaker positions
LED indicators on the front panel
Breaker slots can be set or deactivated on the removable Alarm Card
LED Indicators Green lamps on A and B feeds
Red lamp for alarm indication
Chassis Ground Via studs on back panel, use two hole x 5/8" center lugs, grounding also achieved via rack mounting brackets to yellow zinc chromate steel panel enclosure